Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chips
Item number 56-TR-74UI-S

TandD Logger for light level (lux), UV, temperature and humidity (high-precision model), 4 channels, USB

4.788 SEK

In stock

TandD Logger for light level (lux), UV, temperature and humidity (high-precision model), 4 channels, USB

Request a quote 56-TR-74UI-S

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , , , ,

Other models in the series 6

Description

The 56-TR-74UI-S is the high-precision model of the 4-in-1 logger 56-TR-74UI — the same combination of light, UV, temperature, and humidity, but featuring the included SHA-3151 high-precision sensor, which provides a wider measuring range (-25 to +70 °C, 0–99 %RH) and ±2.5 %RH accuracy in the 15–35 °C / 30–80 %RH range.

Chosen for conservation environments with strict accuracy requirements — museums and archives adhering to international conservation standards (CCI, ICOM), clinical research where both light and climate must be documented with precision, and GMP-validated processes involving light exposure.

Features

  • 4 channels: light, UV, temperature, humidity
  • Light range: 0.01 lx to 130 klx
  • UV range: 0 to 30 mW/cm²
  • T/RH with high-precision SHA-3151: -25 to +70 °C / 0 to 99 %RH
  • T/RH accuracy: ±0.3 °C / ±2.5 %RH (at 15–35 °C, 30–80 %RH)
  • Cumulative light and UV exposure
  • 8,000 data point memory
  • Powered by 1 × AA battery for approx. 6 months

Specification

Measuring channels Light + UV + Temperature + Humidity — 1 channel each
Light measuring range 0 lx to 130 klx (resolution 0.01 lx)
UV measuring range 0 to 30 mW/cm²
Temperature measuring range (S) -25 to +70 °C
Humidity measuring range (S) 0 to 99 %RH
Accuracy T ±0.3 °C (10–40 °C), ±0.5 °C (other)
Accuracy RH ±2.5 %RH (15–35 °C, 30–80 %RH)
Resolution 0.1 °C / 0.1 %RH
Logging capacity 8,000 data points
Communication USB 2.0 Mini-B
Power supply 1 × AA alkaline LR6
Dimensions 55 × 78 × 18 mm

Included

  • 56-TR-74UI-S logger
  • 1 × AA alkaline battery
  • Light/UV sensor 56-ISA-3151
  • High-precision T/RH sensor 56-SHA-3151
  • USB Mini-B cable 56-US-15C
  • Manual set with warranty certificate

Applications

The 56-TR-74UI-S is suitable for conservation institutions with strict climate standards: national archives, world-class museums, cultural heritage properties, clinical research, and GMP facilities requiring combined light, UV, and climate documentation. For standard accuracy, see the 56-TR-74UI.