Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chips

Why a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves it

Published 17 November 2026 at 01:17

Two operators measure the same bushing and get different values. One reads 35.012 mm, the other 35.006 mm. Neither has been careless, but the bore was measured with an instrument that has to be rocked and tilted to find the diameter, and the reading easily ends up on a chord instead of the true diameter. Within a tolerance of a few hundredths of a millimeter, that is the difference between an approved part and a rejected one.

Mitutoyo digital Holtest digital internal three-point micrometer of the Holtest type. Measuring range Ø30–40 mm. Resolution 0.001 mm. Measuring surfaces with TiN coating. Carbide cone and contact point. Digimatic data output, automatic power-off, reset/preset, hold. For blind holes. IP65. Delivered in a plastic or wooden case with the manufacturer's inspection report.

What the instrument is

The Mitutoyo Holtest is a digital internal three-point micrometer for bores in the Ø30–40 mm range. Three measuring surfaces are positioned at 120° intervals around the axis and are pushed outward simultaneously by an inner cone. The instrument therefore centers itself on the axis of the bore, and the display shows the diameter directly, without the operator having to search for a turning point. The resolution is 0.001 mm, and the measuring surfaces are TiN-coated to withstand daily use against steel and aluminum. The instrument is of a type intended for blind holes and has IP65 protection against coolant and chips.

Which problems it solves

The first is operator dependence. With self-centering, the variation between different people and between shifts is reduced. The second is that three contact points also detect out-of-roundness, something a two-point instrument can miss entirely. The third is documentation: the Digimatic output passes the value on to a computer or SPC system, so nobody has to copy numbers by hand. The hold, reset/preset and automatic power-off functions make the instrument practical for continuous use.

When and why it is used

The instrument is used where the diameter of the bore determines the fit: bearing seats, bushings, valve bodies and cylinders. It is zeroed against a setting ring of known diameter, and measurements are then taken at several depths to check for taper and out-of-roundness. These are precisely the cases where a vernier caliper reading is not enough, since the vernier caliper has too low a resolution and is too dependent on the operator.

Three use cases

In a machine shop, machined housings are checked directly at the machine. The operator sees whether the bore is drifting toward the tolerance limit and can compensate for tool wear before anything ends up out of tolerance. At a hydraulics company, cylinder bores and bushings are measured at incoming inspection, where a bore that is a couple of hundredths too large causes leakage in the finished component. In a quality lab, the Holtest is used for traceable bore measurement with an inspection report from the manufacturer, in cases where a two-point measurement does not provide sufficient certainty.

Why it pays off

The instrument is an investment, but it should be weighed against the cost of rejected parts, rework and complaints caused by incorrect bore dimensions. Each measurement is faster because no time is spent searching for the right position. The measured values become comparable between people, and data transfer eliminates transcription errors. Where bores are measured daily, this pays off in reduced variation and fewer discussions about which value is actually correct.

If you want a bore measurement that gives the same answer regardless of who is holding the instrument, take a closer look at the Holtest model for Ø30–40 mm.

Read more

More news