Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the resultVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the result
Item number 56-TR-73U

TandD Handheld Logger for Temperature, Humidity and Atmospheric Pressure (3 Channels). LCD Display, USB

3.835 SEK

In stock

TandD Handheld logger for temperature, humidity, and atmospheric pressure (3 channels). LCD display, USB

Request a quote 56-TR-73U

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , , , , ,

Other models in the series 6

Description

The 56-TR-73U is TandD’s 3-channel handheld logger that measures temperature, humidity AND atmospheric pressure simultaneously in a single unit — perfect for weather documentation, calibration measurements, and quality control where all three parameters are required at the same time.

The included TR-3100 T/RH probe provides 0–55 °C / 10–95 %RH with ±0,3 °C accuracy in the calibration range of 0–50 °C. The built-in barometer measures 750–1100 hPa with ±1,5 hPa accuracy. The logger is approved according to RTCA DO-160E Section 21 for radio frequency emission — meaning it can be carried on board flights as carry-on luggage and used during flight without interfering with avionics. Highly useful for air freight documentation of temperature-sensitive cargo.

Features

  • 3 channels: temperature, humidity and atmospheric pressure
  • Temp/RH with external TR-3100 probe: 0 to +55 °C / 10 to 95 %RH
  • Atmospheric pressure (internal sensor): 750 to 1100 hPa
  • Accuracy T: ±0,3 °C (0–50 °C) / ±0,5 °C / ±1,5 hPa
  • Resolution 0,1 °C / 1 %RH / 0,1 hPa
  • Direct USB 2.0 Mini-B connection to PC
  • 8,000 data point memory (combined for all 3 channels)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • RTCA DO-160E Section 21 approved — can be used in the aircraft cabin
  • Powered by 1 × AA battery for approx. 10 months
  • Front buttons for start/stop, interval selection, display selection
  • Built-in LCD with rotation of all values
  • Specification

    Measuring channels Temperature 1 channel (external TR-3100) + Humidity 1 channel (external) + Atmospheric pressure 1 channel (internal)
    Measuring range T (included probe) 0 to +55 °C, optional: -40 to +110 °C
    Measuring range RH 10 to 95 %RH
    Measuring range pressure 750 to 1100 hPa
    Accuracy ±0.3 °C (0–50 °C, calibration) / ±5 %RH / ±1.5 hPa
    Resolution 0.1 °C / 1 %RH / 0.1 hPa
    Response time (90 %) T/RH: approx. 7 min; Pressure: 4 sec (1 sec interval) or 40 sec (≥10 sec interval)
    Logging capacity 8,000 data points
    Communication USB 2.0 Mini-B, serial (via optional cable 56-TR-07C)
    Power supply 1 × AA alkaline LR6 (included)
    Battery life approx. 10 months
    Dimensions 55 × 78 × 18 mm
    Weight approx. 40 g
    Operating environment -10 to +60 °C, max 90 % RH non-condensing
    Certificates RTCA DO-160E Section 21 (airborne radio emission)

    Included

    • 56-TR-73U logger
    • 1 × AA alkaline battery
    • External T/RH probe 56-TR-3100
    • USB Mini-B cable 56-US-15C
    • Manual set with warranty certificate

    Applications

    The 56-TR-73U is selected for applications where atmospheric pressure is critical: air transport of temperature-sensitive products (pharmaceuticals, biochemical samples, sensitive electronic components), weather documentation, calibration tasks requiring pressure-compensated T/RH values, high-altitude measurements, dive centers, and vehicle testing centers. For simpler T/RH without pressure, see 56-TR-72NW (Ethernet) or 56-TR72A2 (WiFi).