Published 14 October 2026 at 09:02
Two people measure the same cylinder bore, each with their own internal measuring instrument, and get different answers. The difference is a few hundredths of a millimetre, and neither of them has been careless. The instrument has simply tilted slightly, or it was not lying exactly across the largest diameter of the bore. In a 190 mm bore it is easy to end up in that situation.
What a three-point micrometer is
This is an internal micrometer of the Holtest type for the measuring range Ø175–200 mm. The measuring head has three carbide measuring faces, placed 120° apart around the axis. When the head is inserted into the bore, it aligns itself in the centre of the bore. The operator therefore does not have to find the correct position by rocking the instrument and feeling for it, as is otherwise done with a two-point instrument. The instrument is intended for through bores and is supplied in an aluminium case together with the manufacturer’s measurement report.
The problem it solves
When measuring large bores with a two-point instrument, the biggest source of error is the operator’s hand. The tilt, the contact force and the search for the turning point in the reading cause variation between operators and between days. With three contact points, the geometry is fixed. Measuring is faster, and two people get the same value. The carbide faces hold their size for a long time even when the instrument is used daily, which matters when comparing measured values over time.
When and why it is used
The instrument is used when the tolerance is tight and the bore is too large to be measured well with an ordinary vernier caliper or a simple measuring stand. First, the instrument is zeroed on a setting ring of nominal diameter. Then the head is inserted into the bore and the diameter is read. By measuring at several depths, you can see whether the bore is tapered. The accuracy is ±0.008 mm and the scale division is 0.005 mm, which is sufficient for most fits in housings and cylinders.
Three use cases
Hydraulics: when performing acceptance inspection of cylinder tubes, the bore is checked at several depths. Wear and taper are visible immediately, and the measured values can be documented.
Engine and compressor workshops: during overhaul, cylinder bores are measured against the original dimensions to determine whether the liner can be kept or must be replaced. The decision is then based on a repeatable measurement and not on an estimate.
Mechanical manufacturing: after intermediate machining of bearing housings and flanges, the diameter is checked at the machine before the part is passed on. A measurement that is correct already at the first attempt saves a re-clamping.
The economics of it
The cost of a wrongly measured bore is seldom the instrument itself. It is a scrapped part, a rework or a complaint that comes back weeks later. Because the instrument centres itself, measurement uncertainty is reduced, and more people can perform the check without lengthy training. That means fewer rechecks and fewer disputes between production and quality about which dimension actually applies. The manufacturer’s measurement report also provides a traceable starting point for your own calibration.
If you regularly handle bores in the 175–200 mm size range, a self-centering three-point micrometer is a natural complement to the other measuring tools in the workshop or measuring room.