Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the resultVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the result
Item number 56-TR-52I

TandD Compact waterproof temperature logger with external probe. -60 to +155 °C depending on probe

1.734 SEK

In stock

TandD Compact waterproof temperature logger with external sensor. -60 to +155 °C depending on sensor

Request a quote 56-TR-52I

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , ,

Other models in the series 4

Description

The 56-TR-52I is TandD’s compact single-channel logger for temperature with an external probe on cable — featuring the same robust design as the 56-TR-51I but with the probe separated from the electronics, allowing you to measure in locations where the logger unit does not fit or would be damaged. The measuring range extends from -60 to +155 °C, depending on the probe used.

A standard probe is included. Powered by an LS14250 lithium cell for approximately 4 years. Data retrieval requires the communication holder 56-TR-50U2 (sold separately) — optical data transfer eliminates the risk of short circuits caused by wet contacts.

Features

  • External thermistor probe on cable (included)
  • Measuring range -60 to +155 °C (probe-dependent)
  • Fast response time: approx. 80 seconds in air, approx. 7 seconds in stirred water
  • Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C / ±1.0 °C in extreme ranges
  • IP64 splash protection on the logger unit
  • 4-year battery life on a single LS14250
  • 16,000 data points
  • 15 fixed logging intervals (1 second to 60 minutes)
  • Built-in LCD and alarm LED
  • Optical communication via 56-TR-50U2

Specification

Measuring channel Temperature 1 channel — thermistor (external, on cable)
Measuring range -60 to +155 °C (probe-dependent)
Accuracy ±0.3 °C (-20 to 80 °C), ±0.5 °C / ±1.0 °C (extreme ranges)
Resolution 0.1 °C
Response time (90 %) approx. 80 sec in air / approx. 7 sec in stirred water
Logging capacity 16,000 data points
Communication Optical (requires 56-TR-50U2)
Protection class IP64 (logger unit)
Power supply Lithium battery LS14250 × 1 (included)
Battery life approx. 4 years
Dimensions 62 × 47 × 19 mm (excl. probe)

Included

  • 56-TR-52I logger with external temperature probe
  • 1 × Lithium battery LS14250
  • Manual set with warranty certificate
  • NOTE: 56-TR-50U2 holder required for PC connection

Applications

The 56-TR-52I is suitable for applications where you need to measure outside the -40/+80 °C range or need to place the probe at a specific point. Typical applications: ovens, freezers with the probe placed inside the product itself, heating circuits, autoclaves. For the modern Bluetooth version, see 56-TR42A. For a built-in probe instead, see 56-TR-51I.

Additional information
Product Type

Measures

Temperature

Communication

Optical

PDF (1)