Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chips
Item number 56-TR-55I-PT

TandD Compact temperature logger for Pt-100/1000 sensors (sensor not included). Optical data transfer

2.333 SEK

In stock

TandD Compact temperature logger for Pt-100/1000 sensors (sensors not included). Optical data transfer

Request a quote 56-TR-55I-PT

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , ,

Other models in the series 4

Description

The 56-TR-55I-PT is TandD’s compact logger for Pt sensors — connect Pt100 or Pt1000 in 3- or 4-wire configuration via the included input module, and cover temperatures from -199 to +600 °C with high-precision measurement. Pt sensors offer better accuracy and stability over time compared to thermistors, making it the choice for calibration tasks and industrial precision measurements.

NOTE: Pt sensors are NOT included — ordered separately according to application (rod dimension, cable length, IP class). Optical data transfer via 56-TR-50U2 USB holder (sold separately).

Features

  • 1 channel Pt100 or Pt1000 (3- or 4-wire)
  • Measuring range -199 to +600 °C
  • Resolution 0.1 °C
  • High precision and long-term stability — better than thermistor
  • Temperature adjustment function — compensate for calibration errors
  • 16,000 data point memory (Endless or One Time)
  • 15 fixed logging intervals (1 sec to 60 min)
  • Alarm LED for limit exceedance
  • Built-in LCD
  • Lithium battery approx. 4 years operation
  • Optical communication via 56-TR-50U2

Specification

Measuring channel Temperature 1 channel — Pt100 / Pt1000 (3- or 4-wire)
Measuring range -199 to +600 °C
Resolution 0.1 °C
Logging capacity 16,000 data points
Communication Optical (requires 56-TR-50U2)
Power Supply Lithium battery LS14250
Battery Life approx. 4 years
Dimensions 62 × 47 × 19 mm

Included in the box

  • 56-TR-55I-PT logger with Pt input module
  • 1 × Lithium battery LS14250
  • Manual set with certificate of conformity
  • NOTE: Pt sensor and TR-50U2 holder are NOT included

Applications

The 56-TR-55I-PT is suitable for industrial temperature measurements with high accuracy requirements: calibration tasks, process monitoring in the pharmaceutical industry, climate chambers, heat treatment ovens (low temperature), and cryogenic research. For thermocouples, see 56-TR-55I-TC. For voltage, see 56-TR-55I-V.

Additional information
Product Type

Measures

Temperature

Communication

Optical

PDF (1)