Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chips

Here, the measuring surface shouldn’t just grip well, it also has to fit

Published August 27, 2026 at 10:38

On an ordinary micrometer, the measuring faces have a single job: to contact the workpiece. On a blade micrometer, they have two. They must contact the workpiece and they must fit into the space where the dimension sits — and that dual role determines the whole shape of the instrument.

Mitutoyo digital bladmikrometer 75-100 mm med lamellformade maetytor

What it is

A digital blade micrometer with blade-shaped measuring faces.

  • Measuring range 75-100 mm, resolution 0.001 mm
  • Blade-shaped measuring faces for access to narrow grooves and tight spaces
  • Ratchet stop for constant measuring force
  • Hardened measuring faces, IP65

What you measure with it

Dimensions that sit down inside a groove. The width of a groove in a blade or a disc. The diameter at the bottom of a recess on a shaft — a retaining-ring groove, a relief cut, a thread undercut. The thickness of a thin material sitting between two flanges.

All of these dimensions are functional. A retaining-ring groove that’s a few hundredths too shallow means the ring won’t seat fully, leaving axial play in the assembly. But at the same time, they’re invisible to an ordinary micrometer: its round, thick anvil simply won’t reach down into the groove, and measuring across the groove’s edges instead gives you a different dimension that tells you nothing about the actual feature.

Why the blades make the instrument more expensive than its range suggests

Two blades must stay parallel to each other. An ordinary micrometer has circular measuring faces that meet at a point or a small circle — there, a negligible angular deviation matters less. Blades, on the other hand, meet across an entire line, and if they tilt even slightly relative to each other, you end up measuring the diagonal instead of the true distance.

Keeping two thin, wide surfaces flat and parallel across the whole measuring range is what makes the design demanding. It’s also why the ratchet stop matters more here than on an ordinary micrometer: the measuring force must be low and always the same, because a thin blade is exactly as much more flexible as it is thinner.

And that leads to the honest limitation: the blades are the instrument’s most fragile part. A blade bent through excessive tightening or by being used as a prying tool is no longer flat — and a measuring face that isn’t flat measures wrong forever, without anything showing on the outside. A blade micrometer tolerates less rough handling than its price would suggest.

Three typical use cases

  • Grooved shafts: diameter at the bottom of retaining-ring grooves, recesses, and relief cuts.
  • Blades and discs: groove width and thickness of thin components.
  • Incoming inspection: verification of groove dimensions otherwise checked only with a gauge.

Why it pays off

Groove dimensions are often checked with a go/no-go gauge. That’s enough to sort parts, but it tells you nothing about how close to the limit the part is — and therefore nothing about a process that’s starting to drift.

An actual measured value, instead of a pass/fail verdict, gives you that information. And for dimensions sitting down inside a groove, the alternative is often not measuring at all, but trusting that the tool that cut the groove was set correctly — which it was, right up until it wasn’t.

Read more about the 75-100 mm blade micrometer →