Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the resultVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the result
Item number 82-MTM-200-100

Cross Table (Positioning Table) for Kitozoom, MTM-200-100

87.309 SEK

In stock
Request a quote 82-MTM-200-100

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Other models in the series 5

Description

82-MTM-200-100 Video Microscope > Video Microscope Accessories

MTM-200-100 with a measuring range of 200 x 100 mm. Equipped with quick adjustment in the X and Y axes, in addition to one-handed operation capability and adjustable softness in the settings. Highly accurate measurements are guaranteed through the use of the MR measurement system. Position definition of two measuring axes via the SCD screen. This can also be read using the KITEC MAX measuring program via the USB cable connection, so that the displacement in XY-coordinates. Depending on the application (reflection or transmission), the measuring table is delivered with a glass or metal insert plate. NOTE: When using this model with a height adjustment of approx. 60 mm, there will be a residual gap in conjunction with the 0.5x accessory lens, caused by the large working distance of 170 mm.

 

Additional information
Product Type

Specification

82-MTM-200-100 Video Microscope > Video Microscope Accessories

MTM-200-100 with a measuring range of 200 x 100 mm. Equipped with quick adjustment in the X and Y axes, in addition to one-handed operation capability and adjustable softness in the settings. Highly accurate measurements are guaranteed through the use of the MR measurement system. Position definition of two measuring axes via the SCD screen. This can also be read using the KITEC MAX measuring program via the USB cable connection, so that the displacement in XY-coordinates. Depending on the application (reflection or transmission), the measuring table is delivered with a glass or metal insert plate. NOTE: When using this model with a height adjustment of approx. 60 mm, there will be a residual gap in conjunction with the 0.5x accessory lens, caused by the large working distance of 170 mm.

 

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *