Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the resultVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsThree measuring points give the right bore size when the operator’s hand would otherwise decide the result

The machine doesn’t know where the slide is, it knows how much the screw has turned

Published August 24, 2026 at 23:05

A machine axis without a scale actually knows nothing about where the slide is located. It knows how many turns the screw has made, and multiplies that by the pitch. Between that number and the slide’s actual position lies the whole mechanism: the backlash in the nut, wear on the screw, torsion in the coupling, and the screw’s own thermal expansion after an hour of running.

Most of that can be compensated for in the control system. But compensation relies on assumptions about how the machine behaves — whereas a scale measures instead.

Magnescale SJ700A-080 linjaert skalsystem med 800 mm maetomraade

What it is

Magnescale SJ700A-080 — a linear scale system for position measurement on machine axes.

  • Measuring range 800 mm, resolution 5 µm
  • Accuracy ±10 µm for lengths up to 1250 mm, ±15 µm up to 1600 mm
  • Coefficient of expansion 12 ±1 · 10⁻⁶ per degree
  • Operating temperature 0 to 40 °C
  • Cross-section 24 x 25 mm, total length = measuring length plus 120 mm
  • IP54, 3 metre cable

The problem it solves

The scale sits on the slide, not on the drive. That means everything mechanical between the motor and the slide disappears from the measurement. Backlash doesn’t show up as an error — it doesn’t show up at all, because the position is read where the work actually happens. It’s the difference between asking the drive what it thinks and asking the slide where it is.

It’s most noticeable at direction changes. An axis run back and forth without a scale first loses the backlash present in the screw and nut before the slide even begins to move. With a scale in the feedback loop, the system keeps running until the position has actually changed, and the contour comes out the same regardless of which direction you approached from.

Why the coefficient of expansion is chosen as it is

This is the detail that’s easy to misunderstand. A reference standard in a measuring room should have as little thermal expansion as possible — it should be the fixed point that nothing else affects. A machine scale, by contrast, should have an expansion that resembles the machine’s.

12 · 10⁻⁶ per degree is close to that of steel. As the workshop heats up during the day, the machine bed, the scale and the workpiece all grow by roughly the same amount, and the position stays consistent relative to what’s actually being manufactured. A scale with near-zero expansion would instead drift apart from the machine it’s mounted on, and the deviation would grow with temperature and with distance from the mounting point.

And 5 µm is the resolution, not the accuracy. The system displays in five-thousandths, but the guaranteed accuracy over the length is ±10 µm — the distinction being that the scale is a physical graduated ruler with a manufacturing tolerance, while the resolution merely describes how finely the reading is divided.

A practical detail worth calculating in advance: the total length is the measuring length plus 120 mm. An 800 mm scale therefore requires 920 mm of free mounting space along the axis, and that’s usually where a retrofit turns out to be easy or difficult.

Three typical use cases

  • Retrofitting manual machines: digital position readout on a mill, lathe or drill press, where the handwheel would otherwise be the only reference.
  • Renovating older machines: where the screws are worn and a scale restores positional accuracy without replacing the mechanics.
  • Custom and fixture machines: position feedback in self-built setups and measuring stations.

Why it pays off

A worn screw is rarely replaced because someone measured that it’s worn — it gets replaced once parts start coming out wrong, and by then a period of scrap has already been produced. A scale removes the link between the screw’s condition and the part’s dimensions, and thereby pushes that whole investment off indefinitely.

It also removes a quiet cost: the time spent compensating mentally. Always approaching the target dimension from the same direction, allowing for backlash, re-measuring after every direction change — these are routines that work, but they cost seconds every time and depend on the individual operator. With a scale in the system, they’re no longer needed.