Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chipsVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentWhen the measurement has to be taken from an image: how automatic magnification reading makes microscope measurement traceableThe vernier caliper that keeps reading correctly when the scale is covered in coolant and chips
Item number 65-141095089

0-8000mm aluminum vernier caliper, up to 10 meters, microcomputer, 2000+mm measurement

169.123 SEK

In stock
Request a quote 65-141095089

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

Digital vernier caliper with measuring range 0-8000mm, 0.01mm resolution, wireless data transfer, touchscreen, extensive software functions

Reliable reading of measurement results with a resolution of 0.01 mm. High precision with 0.033 mm accuracy. Instead of a standard screen, a microcomputer with a touchscreen is installed. Extensive software functions are available. Measuring force regulation at 8 N for accurate measurement. The measuring force regulation ensures that the measuring force does not exceed a certain limit. This leads to better measurement results. Handmade calipers ensure high precision. The unit uses a rechargeable battery. This eliminates the need for constant battery replacement. Delivered with a calibration certificate according to ISO 17025.

MICS Microcomputer System – Industry 4.0 ready!!

Microtech’s groundbreaking computer-aided MICS system takes calipers/in-house measuring instruments to the next level. The system is equipped with a touchscreen and many software functions, leaving nothing to be desired.

The display features a clearly readable touchscreen. A user-friendly menu ensures easy menu navigation. Up to 100 measured values can be stored via the internal memory. Statistics can be used to retrieve min, max, and average values.

The resolution with the MICS system can be up to 0.0001 mm. GO/NoGO values can be displayed in color. Reading of MIN/MAX values. The formula mode makes it possible to enter calculation formulas with corresponding evaluation. Ambient temperatures can be incorporated into the measurement result via temperature compensation for 7 different materials. For certain measurements, it is necessary to include a mathematical error correction, which is also possible with the microcomputer system. Depending on the working direction, the display can be rotated. The calibration date can be integrated into the software; an external date search is not necessary. The wireless data transfer can be triggered via a timer, touchscreen, or button.

Measuring instruments with the MICS system are delivered with free basic software for Windows, Android, and iOS. Extended functionality can be achieved via a paid update.

MICS software in detail:

  • Go/NoGo (with color coding)
  • Max/min,
  • Storage for up to 100 measured values.
  • Statistics,
  • Timer,
  • Formulas,
  • mm/inch,
  • Preset function,
  • Calibration date,
  • Lock
  • Mathematical and temperature compensation
  • Switch off
  • Brightness
  • Rotation,
  • Rechargeable Li-Po battery

Technical data:

  • Manufacturer: Microtech
  • Order number: 141095089
  • Product: Vernier caliper
  • Measuring range: 0-8000
  • Resolution: 0.01 mm
  • Data output: wireless
  • with touchscreen
  • MICS system with extensive software functions
  • Accuracy: 0.033 mm
  • Measurement of pressure regulation with 8 N
  • Including calibration certificate according to ISO 17025
  • Design: digital
  • Handmade measuring jaws
  • with microcomputer and extensive software
  • Rechargeable battery
  • Length of measuring tip at the bottom: 1000mm
  • Weight: 44 kg
  • Material: aluminium

Aluminium as a material offers the advantages of being very light and at the same time extremely stable.