Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to see the solder joint and the scratch without holding a magnifier over the circuit boardThe cold room was too warm last night, but nobody can show for how longWhy Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrumentVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%How to see the solder joint and the scratch without holding a magnifier over the circuit boardThe cold room was too warm last night, but nobody can show for how longWhy Two Operators Get Different Readings in the Same Bore, and How to Eliminate the DifferenceThe scratch is visible to the eye but not in the report: how to measure directly on the microscope imageWhy a two-point measurement of a bore often shows the wrong diameter, and how a three-point micrometer solves itThree seconds instead of half a minute: how core temperature checks become a routine that actually gets doneA Hundred Bearing Seats per Shift: Read the Deviation Directly Instead of Calculating the DiameterThe hole measures correctly at the mouth but is tapered further in: how to find the fault without cutting up the partOne Second Is Enough to Tell Whether the Core Temperature PassesThree contact points give a bore measurement that doesn’t depend on who is holding the instrument

Digital Gear Caliper Module 1-30: Why a Gear Requires an L-Shaped Specialty Caliper That Measures Both Height and Tooth Thickness Simultaneously

Published July 10, 2026 at 15:54

If you’ve just milled a new gear and want to verify that the teeth are correctly dimensioned, what do you reach for? A standard digital caliper is the wrong answer. Place its flat jaws against the sides of a tooth and you get a number — but NOT the number you’re looking for. A gear is not a set of flat surfaces. It’s an involute surface where the tooth narrows from base to tip, and the dimensions that actually matter for assembly and function are standardized at a specific geometric position.

Gear geometry in brief

A gear has several key diameters and parameters:

  • Outside diameter (Da): The outer circle on which the tooth tips lie.
  • Pitch diameter (Dp): The theoretical circle where two meshing gears roll against each other without slipping. This is the most important geometric reference.
  • Root diameter (Df): The diameter at the base of the tooth (the gap between teeth).
  • Module (m): The standard parameter for metric gear geometry. m = Dp / Z, where Z is the number of teeth. Module 1 = 1 mm of pitch per tooth; module 5 = 5 mm of pitch per tooth.
  • Number of teeth (Z): Counted directly.
  • Pressure angle (α): Typically 20° for modern gears. The angle of the tooth flank at the pitch circle.

For workshop measurement of gears, you mainly check two things: (1) that the module is correct (verified by another method), and (2) that the tooth is correctly dimensioned at the pitch circle.

Chordal tooth thickness and chordal height

Here comes the central mathematical point. At the pitch circle, the tooth has a theoretical thickness that is HALF of the pitch — i.e., half the distance between two adjacent teeth’s midpoints along the pitch circle.

The pitch (p) along the pitch circle = π × Dp / Z = π × m. For module 2: p = 6.28 mm. Half the pitch: 3.14 mm.

BUT — and this is where the complexity begins — the tooth thickness at the pitch circle is NOT 3.14 mm if measured along a STRAIGHT LINE between the tooth’s two flanks. The pitch circle is a circle; if you measure along a straight line (a chord) between the two points where the pitch circle intersects the tooth’s flanks, you get a slightly SMALLER value. This chord is called the ”chordal tooth thickness”:

s_chord = m × Z × sin(π/(2Z))

For module 2, Z = 20 teeth: s_chord = 2 × 20 × sin(π/40) = 40 × sin(4.5°) = 40 × 0.0785 = 3.140 mm.

For module 2, Z = 60 teeth: s_chord = 2 × 60 × sin(π/120) = 120 × sin(1.5°) = 120 × 0.0262 = 3.142 mm.

The difference between the arc (3.14 mm exactly) and the chord is minimal for large tooth counts, but becomes significant for small tooth counts. For module 2, Z = 8 teeth: s_chord = 16 × sin(11.25°) = 16 × 0.195 = 3.121 mm.

Chordal height — the other dimension

For the chord to lie at the level of the pitch circle, the chordal height (the distance from the tooth tip down to the pitch circle at the middle of the chord) must be calculated separately:

h_chord = m × [1 + Z/2 × (1 – cos(π/(2Z)))]

For module 2, Z = 20: h_chord = 2 × [1 + 10 × (1 – cos(4.5°))] = 2 × [1 + 10 × 0.00308] = 2 × 1.0308 = 2.062 mm.

For module 2, Z = 60: h_chord = 2 × [1 + 30 × (1 – cos(1.5°))] = 2 × [1 + 30 × 0.000343] = 2 × 1.0103 = 2.021 mm.

The chordal height is always slightly greater than the module (the ”addendum” in gear terminology is exactly m; chordal height includes a small addition to compensate for the chord’s position below the top of the arc).

How the L-shaped gear tooth caliper works

Now we understand why a standard caliper doesn’t work. To measure a gear’s chordal tooth thickness, we need to:

  1. Place a vertical jaw that rests against the tooth tip and extends DOWN to exactly the chordal height. This depth must be adjustable for different gear sizes.
  2. At that depth, a horizontal jaw measures the distance between the tooth’s two flanks.

That’s precisely the L-shape of the gear tooth caliper. Two separate measuring axes:

  • Vertical axis (depth measurement): 0-30 mm. Manually set to the chordal height h_chord.
  • Horizontal axis (tooth thickness measurement): 0-40 mm. At the selected depth, it measures the tooth’s chordal thickness.

Both axes’ values are read simultaneously on a digital LCD display. The operator calculates the chordal height and chordal thickness in advance (from gear data: module, tooth count), sets the vertical axis, and reads the horizontal axis.

Digitalt kugghjuls-skjutmått modul 1-30, mätområde h:0-30 g:0-40 mm

Practical workflow

Step-by-step measurement on a gear:

  1. Identify the gear data: From the design drawing or from the marking on the gear, read off the module (m) and number of teeth (Z).
  2. Calculate the theoretical values: s_chord and h_chord according to the formulas above. Tables for standard modules and tooth counts are available in all gear reference books.
  3. Set the vertical axis to h_chord: E.g., 2.062 mm for module 2, Z=20. Lock the position.
  4. Place the gear caliper’s depth gauge against the tooth tip: The vertical jaw should rest flush against the top of the tooth.
  5. Read the horizontal axis: The digital display shows the measured chordal tooth thickness.
  6. Compare with the calculated theoretical value: E.g., 3.140 mm.
  7. Calculate the deviation and check against tolerance: Typically DIN class 6-9 for workshop production, with tolerances of 0.010-0.050 mm.

This is normally repeated on 3-4 different teeth around the gear to detect ovality or local manufacturing defects.

Tolerance classes according to DIN 3961/3962

Gear quality is defined through DIN standards with classes 1-12 (1 = ultra-precision, 12 = coarse). Tolerance for chordal tooth thickness depends on class, module, and tooth count:

  • Class 4-5 (precision gears): ±0.005-0.010 mm. Optical instruments, measuring equipment.
  • Class 6-7 (industrial precision): ±0.010-0.020 mm. Ferrari transmissions, robotics gearing.
  • Class 8-9 (workshop production): ±0.020-0.050 mm. Car gearboxes, industrial mechanics.
  • Class 10-11 (coarse production): ±0.050-0.100 mm. Agricultural machinery, construction vehicles.
  • Class 12 (cast gears): ±0.150+ mm. Coarse construction, cement industry.

The gear caliper with 0.01 mm resolution is sufficient for class 6 and lower. For class 4-5, better instruments are needed (a gear measuring center or a chordal micrometer).

Module range 1-30 — what it covers

This specific model measures from module 1 up to module 30. Practical range:

  • Module 1-3: Clockmakers, microscope mechanics, precision tools. Gears up to Ø 60-100 mm.
  • Module 3-5: Car gearboxes, motorcycle transmissions, industrial robotics. Gears Ø 50-200 mm.
  • Module 5-10: Heavy vehicle transmissions, hydraulic motor gearing, wind turbine planetary gears. Gears Ø 100-500 mm.
  • Module 10-20: Massive industrial drives, rolling mills, mining machinery. Gears Ø 300-1500 mm.
  • Module 20-30: Extra-heavy-duty applications. Cement mills, power generators. Gears Ø 1000-3000 mm.

For standard workshop production (automotive, motorcycle, industrial), module 1-30 covers 90% of all measuring tasks.

Alternative methods

Three-wire method: Two steel pins are placed between the teeth and the outer dimension over the pins is measured with a micrometer. This gives a ”measurement over pins” — a different geometric parameter that can be converted to tooth thickness via a formula. More accurate than the gear caliper but more cumbersome.

Gear span gauge: Spans several teeth at once (typically 3-5). Faster for high-volume production. Requires a calibration master.

Gear measuring center (CNC): SEK 300,000-2,000,000. Automated measurement with high precision. For serial production in factory QC.

Optical projection measuring device: SEK 50,000-200,000. Coordinate measurement of the tooth silhouette. For research and quality development.

The gear caliper is the standard for workshop-level measurement: fast, portable, sufficiently accurate for class 6+ manufacturing.

Who needs this

Gear manufacturers: Inspection after milling and grinding before the finished product is shipped out.

Automotive and motorcycle mechanics: When reconditioning gearboxes. Measuring worn gears to determine whether replacement is needed.

Industrial mechanics: Maintenance of gearboxes, transmissions, industrial drives. Wear tracking over operating time.

Clockmakers and watchmakers: Module 1-3 gears in mechanical movements. Spare parts verification.

Model makers and 3D printing technicians: Inspection of 3D-printed gears for prototype mechanisms.

Toolmaker workshops: Special gears for niches where finished products aren’t available.

Schools and technical training institutions: Gear theory and measurement are part of mechanical engineering education.

What you get for your money

Schut digital gear tooth caliper, measuring range module 1-30, height axis 0-30 mm, horizontal axis 0-40 mm, resolution 0.01 mm, digital LCD display, 2 x V357 batteries, hardened ground measuring jaws, ECONOMY LINE build quality. SEK 2,622.

The standard tool for workshop gear measurement in the very common module 1-30 range. For class 6-9 manufacturing and maintenance measurement, this instrument is economical and functionally sufficient. For class 4-5 precision or serial production QC, more advanced alternatives are available.

Read more: Digital gear tooth caliper module 1-30 in the shop →