Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%One and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually gotHow to see the solder joint and the scratch without holding a magnifier over the circuit boardThe cold room was too warm last night, but nobody can show for how longVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%One and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually gotHow to see the solder joint and the scratch without holding a magnifier over the circuit boardThe cold room was too warm last night, but nobody can show for how long

The cold room was too warm last night, but nobody can show for how long

Published 19 November 2026 at 17:28

It often starts on a Monday morning. Someone notices that the cold room is at 9 °C instead of 4 °C, and the only question that matters can’t be answered: how long has it been like that? The round sheet shows one reading on Friday afternoon and the next on Monday morning. In between there is a gap, and that gap can hold the quality of an entire batch.

TandD Temperature logger, 2 channels (1 internal + 1 external, or 2 external), wired Ethernet/LAN. -60 to +155 °C depending on probe. Cloud connectivity

What it is

The TandD TR-71NW is a temperature logger with two measurement channels and a built-in Ethernet connection. Two TR-0106 thermistor probes on cables are included, and the logger also has an internal sensor. The readings are stored in the logger, which holds 16,000 data points, and are uploaded automatically to T&D WebStorage in the cloud or to your own PC running T&D Data Server. The logger can be powered via PoE (IEEE 802.3af), so a single network cable is enough for both power and data.

What problems it solves

The logger replaces manual readings and handwritten lists with a continuous curve. The logging and upload intervals can be selected from 15 fixed steps between one minute and 24 hours. Because the connection is wired, it also works where WiFi is unreliable: in basements, concrete buildings and on factory floors. The accuracy is ±0.3 °C between -20 and 80 °C. With the standard probes the measuring range is 0 to +55 °C, and with other probes it can extend from -60 to +155 °C.

Three use cases

Food production. A cold room and a refrigerated display case can be monitored with one logger, with one probe in each. The curve provides documentation for your self-inspection routines and shows whether a deviation was a door left open during loading or a cooling unit that has begun to lose capacity.

Laboratory. Test chambers, freezers and incubators must hold a certain temperature over time. With a logger on the network, the history is collected in one place, without anyone having to walk around with a handheld thermometer.

Warehouse and maintenance. In a warehouse with temperature-sensitive goods or in a technical room, one probe can be placed near the floor and the other high up. The difference between the levels often shows where the problem actually lies. With fluoropolymer-coated probes, the logger can also be used at high temperatures, for example in process equipment.

Why it pays off

Consider what happens otherwise. A manual round takes time every day, and it only captures a single moment. A deviation during the night or the weekend is only noticed afterwards, and then the whole batch must be assessed without documentation, which often ends in discarding safe goods or in an uncertain decision to sell them. A logger in this price class costs less than a single lost pallet. A battery life of up to 1.5 years with uploads every twelve hours also keeps maintenance low, and PoE saves installation work.

If you want to replace spot checks with a continuous temperature curve, you can read more about the TandD TR-71NW and its specifications here: TandD temperature logger with Ethernet and two channels.

Read more

More news

All news