Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually gotVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually got
Item number 56-TR75A2

TandD Logger for thermocouple types K, J, T, E, S, R, 2 channels (probe not included), wireless WiFi LAN + Bluetooth. Cloud connectivity

2.887 SEK

In stock

TandD Logger for thermocouples type K, J, T, E, S, R, 2 channels (probe not included), wireless WiFi LAN + Bluetooth. Cloud connectivity

Request a quote 56-TR75A2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: , , ,

Other models in the series 16

Description

The 56-TR75A2 is the WiFi logger for thermocouples — 2 channels with support for type K, J, T, E, S, R, measuring range from -199 to +1760 °C depending on sensor selection. It is the only WiFi logger in the TR7 series capable of measuring extremely high temperatures (Type S/R goes up to 1760 °C — perfect for the glass, metal, and process industries).

NOTE: Thermocouples are NOT included — connect them yourself via the screw terminals on the back of the logger. Built-in Vaccine Mode (VFC/CDC compatible) records Max/Min values based on logged data. Encrypted HTTPS upload to the T&D WebStorage Service cloud, compatible with WPA2-Enterprise corporate networks.

Thermocouple compatibility

  • Type K — -199 to +1370 °C (industrial standard)
  • Type J — -199 to +1200 °C
  • Type T — -199 to +400 °C (cryogenic)
  • Type E — -199 to +1000 °C
  • Type S — -50 to +1760 °C (PtRh10-Pt, high temperature)
  • Type R — -50 to +1760 °C (PtRh13-Pt, high temperature)

Features

  • 2 channels thermocouple K/J/T/E/S/R
  • Measuring range up to -199 to +1760 °C (depending on sensor selection)
  • Thermocouple accuracy (excl. sensor): K/J/T/E ±(0.5 + 0.003 × t) °C at ≥-100 °C; S/R ±(1.5 + 0.003 × t) °C at ≥100 °C
  • Cold Junction compensation ±0.5 °C (10–40 °C operating range)
  • Resolution K/J/T/E: 0.1 °C / S/R: approx. 0.2 °C
  • WiFi 802.11 b/g/n with WPA2-Enterprise
  • HTTPS for secure upload
  • 30,000 data point memory
  • Vaccine Mode (VFC/CDC compatible) for pharmaceutical monitoring
  • Bluetooth 4.2 BLE + USB 2.0 for configuration
  • LCD with Max/Min/ALM display for both channels

Specification

Measurement channels Temperature 2 channels — thermocouple K/J/T/E/S/R via screw terminals
Measurement range -199 to +1760 °C (depending on sensor selection)
Cold Junction compensation ±0.5 °C at 10–40 °C operating, ±0.8 °C at other temperatures
Logging capacity 30,000 data points
Measurement modes Normal Mode or Vaccine Mode (VFC/CDC)
WiFi IEEE 802.11 b/g/n with WPA2-Enterprise
Protocols HTTP, HTTPS, SNTP, DHCP, DNS
Other interfaces Bluetooth 4.2 BLE, USB 2.0 Mini-B
Power supply 2 × AA alkaline LR6 / Ni-MH, USB bus, AC adapter 56-AD-05A2/C2

Applications

The 56-TR75A2 is chosen for process industrial temperature measurements where thermocouples are standard — heat treatment, ovens, glass and metal industry, plastic recycling, autoclaves. Vaccine Mode also enables use in pharmaceutical supply chains requiring measurement of extreme temperatures (ultra-low vaccine storage). Thermocouples must be purchased separately according to application. For simpler thermistor-based temperature measurement, see 56-TR71A2. For wired Ethernet, see 56-TR-75NW.

Additional information
Product Type

Measures

Temperature

Communication

Wireless Bluetooth, Wireless WiFi