Hoppa till innehåll
Free shipping over 5.552 SEK ex VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually gotVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually got

The climate no one saw: how a logger reveals the humidity and heat overnight and over the weekend

Published 12 October 2026 at 21:21

It’s Monday morning and rust has started to appear on a pallet of new components. Or a batch has deviating measurement values that no one can explain. Someone remembers that the heating was running low over the weekend, but no one knows how cold or humid it actually got. A thermometer on the wall only shows the current state, not what happened at three o’clock in the morning.

Digital thermohygrograph for permanent monitoring, measuring range -10 to 60°C and 0-100%RH

What a thermohygrograph is

A thermohygrograph measures temperature and relative humidity and stores the values with a timestamp. This model measures from -10 to 60 °C and 0 to 100 %RH without condensation, with a resolution of 0.01 °C and 0.1 %RH. The temperature accuracy is ±(0.1+|T-20|/250) °C, meaning it is at its best near 20 °C. The humidity accuracy is 4 %RH, which is sufficient for monitoring and documentation but not for reference measurement.

The memory holds 500,000 measurements with an adjustable interval. At one measurement per minute, that corresponds to almost a year. Data is retrieved via Bluetooth, SD card or USB and can be displayed as a graph on the built-in e-paper display, in the Windows software or in the app for Android and iOS.

The alarm makes the difference

Logging gives you the answer after the fact. The alarm gives you the chance to act in time. The instrument has audible and visual signals for two upper and two lower temperature limits, four humidity limits and two limits for temperature change. The last one is valuable: a rapid temperature drop often says more about a closed ventilation damper or an open door than the level itself.

Three situations where it is used

Metrology rooms and workshops. Measuring instruments and gauge blocks are calibrated at 20 °C. If the room drifts a few degrees between shifts, it affects both steel and measurement results. A logger shows whether the drift follows solar radiation, shift changes or heat given off by machines.

Electronics assembly and warehouses. Moisture-sensitive components and circuit boards require a controlled environment. Four humidity limits let you set a warning level and an alarm level separately, and the graph shows how long the level was off.

Food production. In dry storage, cold rooms and maturing rooms, documented conditions are often a requirement during audits. The factory measurement report comes with the instrument, and exported curves replace handwritten round sheets.

Why it pays off

The cost is most easily compared with a single scrapped batch, a complaint or an audit remark. In addition, the manual reading of several instruments every day is eliminated. A wall mount and a table stand are included, so it can be set up directly where the problem is suspected, and moved when you want to map another room.

If you want to know what actually happens in your premises when no one is looking, the thermohygrograph is available from us, with specifications and more details on the product page.

Read more

More news

All news