Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually gotVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Absolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementThe dishwasher’s display temperature doesn’t tell you how hot the plate actually got
Item number 64-782321

TESA lifting arm, top mounting, dial indicator diameter 58 mm, compatible with TESA and Käfer dial indicators

1.584 SEK

In stock

Practical retraction device designed to provide optimal access and exposure during surgical procedures. Offers surgeons improved visibility and working space by gently holding tissue aside. Manufactured from high-quality materials for durability and patient safety. An indispensable tool for precision surgery across various medical specialties.

Request a quote 64-782321

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category:

Description

TESA lever, dial 58 is a TESA precision instrument from the ECONOMY series — used for workshop measurement, inspection, and reference work in machine shop and manufacturing environments. Hardened and ground reference surfaces ensure repeatable measurements; the instrument is designed for handheld or fixture-mounted use depending on the workshop application.

Hardened and ground reference surfaces and contact points for repeatable measurements; matched to TESA precision quality class. The instrument is designed for handheld or fixture-mounted use depending on the workshop application, and integrates with standard inspection workflows in metrology labs and machine shop QC stations.

Usage: position the instrument against the workpiece reference surface or feature, and perform the measurement according to the instrument’s standard procedure (depending on type — direct reading, comparative deviation, go/no-go verification, or wrung-stack reference). Zero-verify against the setting standard during periodic verification and document with a calibration certificate. The instrument’s design supports both one-off inspection and back-to-back QC workflows.

Common applications: workshop incoming inspection of components, on-machine setup checks, fitter and toolmaker bench measurements, calibration lab reference work, and QC workflows within the TESA product line. The RETRACTION LEVERS category is the standard workshop tool for the measurement/reference task covered by this product.

Features

  • TESA lever, dial 58
  • Hardened, ground reference surfaces for repeatable measurements
  • TESA build quality
  • Suitable for workshop QC, calibration lab, and bench measurement applications

Specifications

Manufacturer TESA
Type Retraction levers
Article number 64-782321

Compatible accessories

Compatible accessories: TESA setting standards and reference standards for periodic verification of accuracy at known dimensions; calibration certificates (ISO 17025) upon initial delivery and during periodic verification — typically a 12-month interval for production floors, 6 months for high-volume inspection chains; TESA protective cases and bench storage; TESA spare parts and consumables where applicable.

Additional information
Weight 0,008 kg
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *