Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm for three hours last night, but no one knows when it happenedAbsolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurementVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The cold room was too warm for three hours last night, but no one knows when it happenedAbsolute measuring system and tolerance display turn the vernier caliper into a quick yes or no at the benchThe hole that is measured correctly in two seconds: how a plug gauge decides whether 55H7 is within toleranceOne and a half turns instead of thirty: how to cut measuring time in serial samplingThe thread that looked right but wouldn’t screw in: how a Go/NoGo gauge settles it in secondsThe vernier caliper shows three decimals, but does it match a known reference?How to Eliminate Glare When Inspecting Shiny Solder Joints and Ground Surfaces on a ScreenThe thermometer read 72 degrees when the meat was only at 69, and nobody noticed until the inspectionUsing the Same Thermometer for Raw and Cooked Meat Is a Risk That Two Colors SolveThe temperature check that is no longer written on paper an hour after the measurement

The cold room was too warm for three hours last night, but no one knows when it happened

Published 28 November 2026 at 06:41

Monday morning, the cold room display reads 4 °C, just as it should. But the compressor has been close to giving up all weekend, and no one knows whether the goods were ever warmer than permitted. A reading on site only tells you how things are right now, not how they have been. That is the gap a logger fills.

TandD Wireless temperature logger with external probe, large battery compartment (battery not included). Measuring range -60 to +155 °C depending on probe. Bluetooth

What it is

The TandD RTR502BL is a wireless temperature logger with an external thermistor probe on a cable. The probe sits at the measuring point, while the logger unit itself is placed where it is protected. The measuring range is -60 to +155 °C depending on the selected probe, with a resolution of 0.1 °C. Accuracy is ±0.3 °C in the range -20 to 80 °C and becomes somewhat wider towards the extremes.

What sets this particular model apart is the large battery compartment. With an LS26500 C-cell lithium battery (sold separately), the battery lasts about four years, four times longer than in the standard model. The logger stores 16,000 data points, has 15 fixed logging intervals from one second to 60 minutes, and an LCD that shows the current temperature and a low-battery warning. Configuration is done via Bluetooth 4.2 and a mobile app, and data is transmitted wirelessly to a base unit within approximately 150 meters line of sight.

What problem it solves

Spot checks miss deviations. A door left open, a defrost cycle that runs away or a controller that drifts only shows up in a continuous curve. The logger gives you time and duration, which is exactly what an auditor, a customer or a troubleshooter asks for.

Three ways to use it

Food production and storage. The probe is placed in the cold room or in a refrigerated display case while the logger sits outside, where the cable won’t be pinched by the door. The curve forms the basis for your self-monitoring records and shows whether a deviation lasted a few minutes or a whole night.

Laboratory. Freezers, incubators and test cabinets need to be monitored over time. The range down to -60 °C also covers ultra-low freezers, and the external probe means measurement takes place inside the volume without the door having to be kept open.

Maintenance and installations. When troubleshooting heating systems, ovens or process liquids, the probe can be attached to pipes or immersed in the medium. A day’s log shows whether the control is oscillating, something a single spot reading rarely reveals.

Why it pays off

The cost of a logger is small compared with a pallet of wasted goods or a lost production batch. Four years of battery life also means that no one has to go out and replace batteries at hard-to-reach or fixed measuring points, and that your documentation doesn’t develop gaps because a battery ran out. You spend your time reading the curve when something deviates, not walking around taking readings.

If you need to document temperature over time at a location where you can’t be present yourself, this logger is a straightforward and durable choice.